Fairborn
Dock Seal

Highest Quality

Fairborn is dedicated to the efficient production of the highest quality products. This commitment provides for product life expectancy far beyond any competitive model and ensures our customers maximum value.

The pride in workmanship of our experienced personnel, combined with the utilization of the finest grade raw materials, assures products of the highest caliber.

We employ extensive tests at every stage of manufacture and subject the finished product to strict environmental testing to assure each unit will out-perform anything else on the market.

Technical Assistance

Fairborn's commitment to service is supported by a qualified nationwide representative network, and our experienced sales, engineering and management staff. This expertise ensures our success in providing Fairborn customers the best tailor fit product for their specific needs.

Please call us at (800) 262-1188 for any additional information or for assistance in designing a unit that will enhance a facility's aesthetic value, while saving costly energy dollars.

SERIES 1000
Foam Dock Seal
with Fixed Head Pad


The Series 1000 Dock Seal provides airtight protection to the loading dock area during material handling operations. The Series 1000 is most effective when servicing uniform vehicles at a dock having common parameters.

The vehicle positioned at the dock compresses the resilient foam pads, eliminating the gap between the facility and the vehicle body.

To ensure maximum durability, the Series 1000, 1200 and 1400 are available in our superior performance materials. A unit constructed of Dynalon will ensure superior weather-ability and wear characteristics.

As an option, the full height of the unit may be further reinforced with our exclusive Dyna-Armor.

Suggested Specification:

Series 1000 Foam Dock Seal with Fixed Head Pad, as manufactured by Fairborn USA Inc., Upper Sandusky, Ohio.

Dock seal shall have a Dynalon base fabric, or other fabric as specified. The Dynalon cover shall enclose a polyurethane foam pad, which is to be chemically welded to a 2" thick, pressure treated wood frame, kiln dried before and after treating. (Steel frame is optional.) The cover shall wrap behind the wood frame and be secured with stainless steel staples for weather-tight construction. Adequate air exhausts and drain holes are to be provided in covers, and both shall be designed to prohibit moisture infiltration. Side pads shall include full length, highly visible guide stripes. Mounting hardware shall have a rust resistant coating.

Standard unit shall consist of two side pads that mount vertically along both sides of the door opening. Unit shall have one head pad that mounts horizontally between or across the top of the side pads.

Here's how a performance based specification would be written:

FABRIC: Dock seal or shelter shall incorporate a Dynalon cover having the characteristics listed below. All bidders must submit certified test results with bid. The manufacturer shall state the characteristics of the fabric offered and that all tests are done in accordance with Federal Standard 191 and the specific method as listed below. Wear characteristics of any substitute material shall meet or exceed performance specifications.

Summary of properties of fabrics per Federal Standard 191

Coated Fabric: Dynalon
Tear strength (Per Lbs., Method 5134): 300 x 300
*Abrasion Resistance (Cycles, Method 5306): 6000
Tensile Strength (Per Lbs., Method 5100): 1200 x 1200
Cold Resistance (At -40°F, Method 5874): Pass

Coated Fabric: Dynaflex
Tear strength (Per Lbs., Method 5134): 165 x 165
*Abrasion Resistance (Cycles, Method 5306): 1250
Tensile Strength (Per Lbs., Method 5100): 550 x 575
Cold Resistance (At -40°F, Method 5874): Pass

*H-22 Wheel, 1000 Gram Load, End Point-First Exposure to Base Fabric.


SERIES 1400
Foam Dock Seal
with Head Curtain


The Series 1400 accommodates a wide range of vehicle and door height variations by the means of a full width head curtain, held taut by tension straps at each end. The supported head curtain is sloped to ensure adequate drainage.

A split curtain, adjustable by the means of pull ropes and an intermediate foam pad are a few of the head curtain options.

Suggested Specification:

Series 1400 Foam Dock Seal with Full Width Head Curtain, as manufactured by Fairborn USA Inc., Upper Sandusky, Ohio.

Dock seal shall have a Dynalon base fabric, or other fabric as specified. The Dynalon cover shall enclose a polyurethane foam pad, which is to be chemically welded to a 2" thick, pressure treated wood frame, kiln dried before and after treating. (Steel frame is optional.) The cover shall wrap behind the wood frame and be secured with stainless steel staples for weather-tight construction. Adequate air exhausts and drain holes are to be provided in covers, and both shall be designed to prohibit moisture infiltration. Side pads shall include full length, highly visible guide stripes. Mounting hardware shall have a rust resistant coating.

Standard unit shall consist of two side pads that mount vertically along both sides of the door opening. The head curtain shall be secured at the building face by the means of a pressure treated, kiln dried before and after treating, 2" x 4" wood head frame. The 2" x 4" wood frame shall be mounted over the top of the side pads with the head curtain tapering away to provide for adequate drainage. Unit shall include intermediate "Scotchply™" stays, a front tubular metal support and tension straps to keep head curtain taut. The support tubing shall be held in place by a fabric sleeve sewn into the head curtain.

Here's how a performance based specification would be written:

FABRIC: Dock seal or shelter shall incorporate a Dynalon cover having the characteristics listed below. All bidders must submit certified test results with bid. The manufacturer shall state the characteristics of the fabric offered and that all tests are done in accordance with Federal Standard 191 and the specific method as listed below. Wear characteristics of any substitute material shall meet or exceed performance specifications.

Summary of properties of fabrics per Federal Standard 191

Coated Fabric: Dynalon
Tear strength (Per Lbs., Method 5134): 300 x 300
*Abrasion Resistance (Cycles, Method 5306): 6000
Tensile Strength (Per Lbs., Method 5100): 1200 x 1200
Cold Resistance (At -40°F, Method 5874): Pass

Coated Fabric: Dynaflex
Tear strength (Per Lbs., Method 5134): 165 x 165
*Abrasion Resistance (Cycles, Method 5306): 1250
Tensile Strength (Per Lbs., Method 5100): 550 x 575
Cold Resistance (At -40°F, Method 5874): Pass

*H-22 Wheel, 1000 Gram Load, End Point-First Exposure to Base Fabric.

Contact Us
PDA Inc.
Don Dobesh
127 N. Covell
Sioux Falls, SD  57104
(605) 332-2630
Toll Free: 1-800-653-2630
Fax: (605) 332-7064
Email: don@pdainc-sd.com